Operation
Silvamatic Control Unit (continued)
Suck Back Device
The Silvamatic control incorporates a suck back
device which operates on all open outlets while
the selector lever is in by-pass.
This prevents the boom nozzles dripping if the
tractor PTO is running while the unit is not
spraying.
Self Cleaning Filter
A self cleaning filter is incorporated in the control
unit to remove impurities from fluid pumped to
the boom. While the compensating pressure
regulator is operating, the filter is self cleaning
and the impurities which are removed are sent
back to the tank.
To inspect the filter, remove the two U shaped
wires that retain the compensating return hose
and remove the filter. If cleaning is necessary
use a soft brush. When reinstalling the filter take
care that the pointed end is towards the outside
of the control unit. Refer to the diagram on the
previous page
Spray Booms
A variety of booms may be used with Silvan
linkage sprayers depending upon the model and
field application. All have stainless steel
spraylines fitted with non-drip fan jet nozzles.
Booms are part of the standard equipment on
some models or in other cases they may be
installed by the dealer or owner.
On all types of boom, the setting of the correct
operating height is most important to achieve a
uniform spraying pattern. This needs to be at a
height above the target which will achieve 50%
overlap of the spray from adjacent nozzles - refer
Calibration section of this manual.
Always ensure that the boom is unfolded in a
safe area where it will not foul any other objects.
Field Boom
Field booms of 6 or 8 metre width are of
galavanized steel truss construction. The three
section fold allows the outer arms to break back
if an obstacle is contacted and automatically
return to the operating position when passed.
For transport the boom is folded horizontally by
swinging the outer arms rearwards through 180
0
until against the fixed centre section, where they
are retained by the action of the hinge springs.
The arms are simply folded outwards to the
spraying position when required.
The rear uprights of the sprayer frame include a
series of holes to enable the boom to be attached at
a height suitable for the tractor size and spraying
application. Final spraying height is regulated by use
of the tractor linkage control.
FieldMaster Boom
FieldMaster booms in 10 and 12 metre widths are of
galvanized steel truss construction with a deep front
leg on the boom section to protect the spray nozzles
from damage. The three section boom features
double folding outer arms for compact and
convenient transporting.
The suspension system operates in the spraying and
transport positions through a parallelogram linkage
with tension springs and shock absorbing dampers.
Boom height is manually adjusted by a crank and
cable mechanism.
To fold the boom for transport, swing the outer arm
up and over, on to the support saddle of the inner
arm. Swing the inner arm horizontally rearwards
through 180 degrees until it rests across the centre
section, where it will be held by the action of the
spring in the hinge. Repeat for the other side.
Reverse the process to return the boom to the
operating position.
Adjusting Spraying Height
To adjust the spraying height first set the sprayer at
the approximate height with the tractor linkage then
adjust the boom lift. Insert a suitable bar through the
holes in the winch shaft on the right hand side of the
boom support. Lift the locking pawl from the ratchet
and wind the winch shaft to the required boom
height. Reset the locking pawl to hold the boom in
position then remove the bar from the winch shaft.
Check that the boom is horizontal. If levelling is
needed this can be done by adjusting the length of
the lifting cables. Lower the boom to minimum height
and fully unwind the cables. Remove the U-clamp
from the cable on the side to be raised, adjust the
cable length and retighten the clamp. Raise the boom
and check whether it is level.
The boom lift requires little maintenance but care
should be taken to ensure that the linkage arms are
not allowed to become loose, allowing sideways
movement of the boom. The lock nuts should be
kept sufficiently tight to eliminate side clearance
without the linkage binding. If the boom height setting
restricts suspension travel, then the suspension
assembly will have to be raised or lowered on its
mountings.